Get your free estimateHVAC Before & After in Enterprise, NV
Pictures of a job done right are worth more than any sales pitch. Below you’ll find real-world examples of the work we do across Enterprise, NV, written up the way we’d walk you through it in your own driveway: what was broken, what we fixed, and what the house felt like afterward. When the photos land in the gallery slots, you’ll see the actual equipment and the actual results.
Styles & brands we work with
- AC repair
- Furnace & heating
- Heat pumps
- Ductless mini splits
- Carrier
- Trane
- Goodman
Recent Transformations
AC Repair: Failing Capacitor on a 2012 Carrier Split System, Southeast Enterprise
Before
AfterThe house was warming up fast on a 108°F afternoon, and the outdoor unit hummed without the compressor ever kicking on. Our technician found a bulging start capacitor and a contactor with pits burned into the plate – two small parts that stop a whole system cold. We replaced both, tested the compressor under load, and had cold air moving through the return within an hour; the homeowner said the house reached 74°F before sundown. The repair is guaranteed for 365 days under our Done Right Promise.
Furnace Repair: Igniter Replacement on a Goodman 80% Gas Furnace, North Enterprise
Before
AfterThe system would call for heat, the blower would run, and nothing would light – classic failed hot-surface igniter. Cold desert nights in January make that a comfort emergency, not a nuisance. We swapped the igniter (most of these run $150-$300 parts and labor, priced in writing before we touched a tool), verified the flame sensor reading, and confirmed a steady burn on both the low and high fire stages. The furnace lit on the first call and held the setpoint all night.
AC Repair: Refrigerant Leak and Recharge on a Trane R-410A System, Executives at the Park Area
Before
AfterTwo summers of adding refrigerant without finding the source is a short path to a burned-out compressor, and that’s exactly what this homeowner was facing. We pressurised the lines and found a pinhole leak at a factory flare connection on the liquid line. After brazing the joint, we pulled a deep vacuum, recharged the system to factory spec, and confirmed superheat and subcool were back in range. A refrigerant recharge – that means refilling the fluid that moves heat out of your home – only makes sense once the leak is sealed, and this time it was.
Furnace Repair: Induced Draft Blower Replacement on a Lennox G61, West Enterprise

The furnace was tripping the pressure switch and shutting down mid-cycle, which is its way of saying it can’t safely vent exhaust. We tested the inducer motor and found it drawing high amperage and seizing after a minute of run time. Replacing the inducer restored proper draft and cleared the pressure-switch fault. This is also a safety catch worth flagging – a furnace that can’t vent can leak carbon monoxide, and it should never be run waiting on a part if the venting has failed.
AC Maintenance: Deep Tune-Up on a Rheem 3-Ton Condenser, Sunrise Manor Area

This unit had been running hard for three seasons without a cleaning, and the condenser coil was packed with cottonwood fuzz and dust – the kind of buildup that quietly pushes head pressure up and efficiency down. We washed the coil, cleaned and balanced the blower wheel, checked capacitor values, recorded static pressure, and confirmed the charge against the manufacturer’s table. Nothing needed replacing, but the homeowner got a written report of exactly what was found, what we fixed, and what to watch. Flat-price maintenance, and our technicians aren’t paid on what they sell, so the report is honest.
AC Repair: Contactor and Fan Motor on a York Unit, Enterprise Foothills

When the condenser fan stops turning while the compressor keeps running, the system overheats and the whole thing shuts down. We found a contactor with heavy pitting and a fan motor at the end of its winding life. Both were replaced together – doing one without the other just postpones the next failure. The result: the condenser fan ran at full speed, head pressure settled back into range, and the house cooled back to the setpoint within 45 minutes. Written price before we started, written guarantee at the end.
Want Results Like These?
If your AC is short-cycling, your furnace won’t light, or you just want a tune-up before the season turns, call us at (844) 797-9490. We’ll give you a written price before any work starts, send a Threshold Verified technician to you by name and photo, and back every repair with our 365-Day Done Right Promise. Estimates are free – let’s see what your system needs.